Protocol specification
Communication with EYE+ takes place via a simple text-based ASCII protocol. The client sends a command, EYE+ responds with a status code followed by a message.
Information: An ASCII command must be followed by a unique control character LF (\n or ASCII code 0x0A) for the line break.
Commands
The command must be written in lower case with underlined separators (e.g. get_parameter). There must be a space between the command and the parameter and between the parameter and the value. You can find all available commands in the Commands section.
Answer
The server responds to each command from the client with a code that informs the client about the status of the command. The response always takes place in the same way:
<response_code>␣<further information>\n
If the response contains more than one line, the number of lines is added after <response_code>.
<response_code>␣<n>␣<further information>\n
<further information>\n
...
<further information>\n
| <response_code> (ASCII) | Description |
|---|---|
| 200 | The command was executed successfully |
| 201 <n> | The command was executed successfully and contains <n> lines in the output |
| 4xx | Error from client (invalid parameters, command not permitted in current state,...) |
| 5xx | Error from server (image acquisition timeout, calibration invalid, ...) |
Error codes
In the event of an error, the error code is followed by a clear description of the error.
| ASCII | Description |
|---|---|
| 401 | The command received is unknown. |
| 402 | The specified argument is not valid for this command. |
| 403 | The system is not in production status. Make sure that a recipe has been started in production. |
| 407 | The requested programme was not found. Check the selected programme number. |
| 409 | The system is not in a valid state. |
| 503 | Timeout reached. |
| 519 | Calibration invalid. Check camera and robot calibration. |