SetSlot (SS)
Activates a single station. The station of the other stations is not changed.
Input
Syntax: SS{SLOTNUMBER};{STATE}
| {SLOTNUMBER} | Corresponds to the station number |
| {STATE} | 0: Sets the station offline 1: Sets the station online This is an optional parameter. If no {STATE} is specified, then the station is activated! |
Output
| Command Response | Description |
|---|---|
| 0 | Command was processed successfully |
| 1 | Execute not successful |
| 2 | Incorrect syntax |
| 3 | Serious error during execution |
| 4 | Function not active or manually deactivated |
| 9 | EasySightPro® will be closed |
Example
Activates the station number 0.
Copy
SS0;1
0
Deactivates the station number 0.
Copy
SS0;0
0