TriggerAndWait (TRIGW)

Triggers a station and takes a new picture and waits for the end of the test.

Input

Syntax: TRIGW{SLOTNUMBER}

{SLOTNUMBER} Corresponds to the station number.
If -1, all stations are controlled.

Output

Information: The response will be sent as soon as the inspection is completed and the results are ready.

Command Response Description
0 Command was processed successfully
1 Execute not successful
2 Incorrect syntax
3 Serious error during execution
4 Function not active or manually deactivated
9 EasySightPro® will be closed

Example

Takes a new image for station 0 and waits for the end of the inspection. The response 0 is sent only after the end of the inspection.

Copy
TRIGW0
0

Takes a new image for stations. The response 0 is sent only after the end of the inspection.

Copy
TRIGW-1
0