Baumer VCXG.I
The VCXG.I series has up to 4 outputs for direct connection of illumination.
In conjunction with EasySightPro® multi-image acquisition, up to 4 illuminations can be used per inspection.
Warning: The following limits must be observed at the outputs: maximum 1.5A permanently (sum of all outputs) and maximum 2.5A for 1 second per output.
The camera can alternatively be supplied via POE (Power over Ethernet), whereby the supply via the IO port is preferred internally.
| Pin | Color | Description | Connection from / to | Comment |
|---|---|---|---|---|
| 1 | Brown | Power VCC | Power supply +24V | |
| 2 | Blue | Power GND | Power supply GND | |
| 3 | White | IN1 (Line 0) | Hardware Trigger | Optional trigger signal +24V |
| 4 | Green | OUT1 (Line 4) | Illumination 1 +24V | Direct connection of the lighting |
| 5 | Pink | IN2 (Line 1) | - | |
| 6 | Yellow | OUT2 (Line 5) | Illumination 2 +24V | Direct connection of the lighting |
| 7 | Black | OUT3 (Line 6) | Illumination 3 +24V | Direct connection of the lighting |
| 8 | Gray | IN3 (Line 2) | - | |
| 9 | Red | OUT4 (Line 7) | Illumination 4 +24V | Direct connection of the lighting |
| 10 | Purple | IN4 (Line 3) | - | |
| 11 | Gray-Pink | GND (IO) | Power supply GND | |
| 12 | Red-Blue | Power (IO) | Power supply 24VDC |