Baumer VCXG.I

The VCXG.I series has up to 4 outputs for direct connection of illumination.

In conjunction with EasySightPro® multi-image acquisition, up to 4 illuminations can be used per inspection.

Warning: The following limits must be observed at the outputs: maximum 1.5A permanently (sum of all outputs) and maximum 2.5A for 1 second per output.

The camera can alternatively be supplied via POE (Power over Ethernet), whereby the supply via the IO port is preferred internally.

Assignment of the camera IO cable
Pin Color Description Connection from / to Comment
1 Brown Power VCC Power supply +24V  
2 Blue Power GND Power supply GND  
3 White IN1 (Line 0) Hardware Trigger Optional trigger signal +24V
4 Green OUT1 (Line 4) Illumination 1 +24V Direct connection of the lighting
5 Pink IN2 (Line 1) -  
6 Yellow OUT2 (Line 5) Illumination 2 +24V Direct connection of the lighting
7 Black OUT3 (Line 6) Illumination 3 +24V Direct connection of the lighting
8 Gray IN3 (Line 2) -  
9 Red OUT4 (Line 7) Illumination 4 +24V Direct connection of the lighting
10 Purple IN4 (Line 3) -  
11 Gray-Pink GND (IO) Power supply GND  
12 Red-Blue Power (IO) Power supply 24VDC